Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Environmental Meters
Created with Pixso. SL-1256DOS Digital Dosimeter Noise Dose Meter 60-130dB 70-140dB Ranges

SL-1256DOS Digital Dosimeter Noise Dose Meter 60-130dB 70-140dB Ranges

Brand Name: Bestone
Model Number: SL-1256DOS
MOQ: 1
Price: US$235
Delivery Time: 5-8 working days
Payment Terms: T/T,Western Union,MoneyGram
Detail Information
Place of Origin:
CHINA
Certification:
CE,ROHS,ISO
Model NO.:
SL-1256DOS
Measurement Ranges 2:
70 – 140 : 70 – 140dB (a And C)
Peak Ranges 1:
60 – 130 : 93 – 133dB Peak
Peak Ranges 2:
70 – 140 : 103 – 143dB Peak
Frequency Weightings:
RMS Detector: A Or C
Frequency Weightings 2:
Peak Detector: C Or Z (Linear)
Time Weightings:
Fast And Slow (RMS Detector)
Exchange Rate:
3, 4, 5 Or 6dB
Criterion Level : 80, 84, 85 Or 90dB:
At 0.1dB Above The Top Of The Selected Measurement
Transport Package:
Gift Box And Carrying Case
Specification:
CE, ROHS
Trademark:
BESTONE
Origin:
China
HS Code:
9030409000
Production Capacity:
1000000
Packaging Details:
pp box and white box and outer carton
Supply Ability:
more than 500pcs per month
Highlight:

60-130dB Digital Dosimeter

,

70-140dB Noise Dose Meter

,

Logging Capability Noise Dose Meter

Product Description
Digital Dosimeter Logging Noise Dose Meter
Professional Noise Exposure Measurement Device
Key Features:
  • This Noise Dose Meter meets the GB/T 15952 standard.The Noise Dose Meter measure the frequency weighted noise exposures and peak sound levels simultaneously.
  • Simple operation, including direct read–out of results.
  • Eight built–in standard dose measurement setups : OSHA80, OSHA90, MSHA-80, MSHA-90, DOD, ACGIH, ISO85 and ISO90.
  • Nine user – defined measurement setups.
  • A single sound level meter (SLM) setup.
  • A single sound level meter (SLM) setup.
  • 50 dose (DATA) result stores.
  • Keypad lock protects meter against accidental operation.
  • Timers support pre–selection of measurement time and duration.

    The meter is ideal for quick on–site surveys and for monitoring personal noise exposure in accordance with European ISO or USA OSHA, MSHA, DOD AND ACGIH standards.

    The meter is two overlapping measurement ranges : 60 – 130 & 70 – 140dB, A & C RMS weightings, Linear & C Peak weightings, Fast & Slow time weightings, and energy exchange rates (Q) of 3, 4, 5 & 6. In dose measurement mode, it display % dose, % dose projected for an 8 hour period, peak level and measurement duration.

    For countries that are subject to European Union regulations or the equivalent ISO standards, the meter measure the daily sound exposure level (LAeq,8hr,Pa2h according to IEC 61252, which is identical with the L EX,8h required by ISO 1999), while for USA OSHA/MSHA regulations they measure the Time Weighted Average level (TWA).

    When used as a sound level meter it display sound level, time–averaged (L Aeq) sound level, peak and sound exposure level (SEL).

    The meter is automatic run timing facilities controlled by the built-in clock and time–history recording capabilities. Sampling times can be specified between 1s and 1 hour, while storage is 120000 data points.

    The meter is able to measure and save up to five specified Ln values (Statistical noise levels). Run duration, start and stop times preset, and other setting via the meter keys

Applications

This personal noise dose meter evaluates workplace noise conditions by measuring accumulated noise exposure. The data helps companies comply with noise regulations and implement necessary noise reduction measures to prevent acoustic trauma and noise-induced hearing loss among personnel.

Measurement Principle

The meter quantifies noise exposure using the DOSE parameter, representing % noise exposure relative to 90dBA for 8 hours (100% DOSE). Different criteria are available to meet international legislation requirements. The device supports both 3dB and 5dB exchange rates, where sound level increases correspond to dose doubling at different rates.

Technical Specifications
Standard Applied IEC61252, ANSI S1.25-1992 for dose meter and sound exposure meters. IEC 61672-1-2013 Class 2
Microphone 1/2-inch electret condenser microphone with 31-inch integral cable
Display Liquid Crystal Display
Measurement Ranges (Linearity and Indicator ranges at 4KHz) 60 – 130: 60 – 130dB (A and C)
70 – 140: 70 – 140dB (A and C)
Peak Ranges (C-weighted or Linear Peak over the top 40dB of each measurement range) 60 – 130: 93 – 133dB Peak
70 – 140: 103 – 143dB Peak
Frequency Weightings RMS Detector: A or C
Peak Detector: C or Z (Linear)
Time Weightings Fast and Slow (RMS detector)
Exchange Rate 3, 4, 5 or 6dB
Stabilization Time 10 seconds from power on
Threshold and Criterion Levels (From the setup, predefined in the built-in setup according to applicable standards) User–defined setups in the following ranges:
Threshold Level: 70-90dB in 1dB steps
Criterion Level: 80, 84, 85 or 90dB
Criterion Level: 80, 84, 85 or 90dB At 0.1dB above the top of the selected measurement range
At 0.1dB above the top of the selected measurement range Under–Range Indications
High Level Detector 115dB
Keypad Lock Lock and unlock by pressing key combinations: Up and right arrows to lock; left and down arrows to unlock
Clock Real–time clock with calendar
Memory Results from 50 measurements can be stored for later viewing and download
Measurement Control Measurement Duration: May be set to 5, 10, 15, or 30 minutes or 1, 2, 4, 8, 10, 12, or 24 hours
Timers Up to 16 timers (automatic start and stop) can be set (maximum up to one month ahead of measurement time)
Timer Controlled Started / Stop Set up from the meter keypad
Logging All measurement parameters values can be logged
Logging Period (LP) 1s, 2s, 5s, 10s, 15s, 20s, 30s, 1min, 2min, 5min, 10min, 15min, 20min, 30min or 60min
Logging Capacity 120000 values can be stored at any one time
Setup Eight built–in (predefined) default setups are included. Nine additional user–defined setups can be stored
Output USB interface
Power Supply 4x1.5V AAA Size (UM-4) Battery
Battery Indicator Symbol indication battery voltage level in 4 steps. Indicator flashes when voltage is insufficient for operation
Operating Temperature & Humidity 0-50ºC (32 to 122ºF) ,10-90%RH
Storage Temperature & Humidity -10-60ºC (14 to 140ºF) ,10-75%RH
Size 140x72x34mm
Weight Approx. 350g (including batteries)
Standard Accessories Main Unit
  External Probe
  Screwdriver
  Carrying Case (B04)
  Operation Manual
Standard Setups
Setup OSHA-80 OSHA-90 MSHA-80 MSHA-90 DOD ACGIH ISO-85 ISO-90 User1-9 SLM
Measurement Range (dB) 70–140 70–140 70–140 70–140 70–140 70–140 70–140 70–140 70–140 70–140
Time Weighting Slow Slow Slow Slow Slow Slow Fast Fast Fast Slow
Frequency Weighting A A A A A A A A A A
Peak Frequency Weighting Lin Lin Lin Lin Lin Lin C C C Lin
Exchange Rate 5 5 5 5 4 3 3 3 3 3
Threshold (dB) 80 90 80 90 80 80 70 70 80 N/A
Criterion Level (dB) 90 90 90 90 85 85 85 90 90 N/A
Allow User to Change Setup No No No No No No No No Yes Yes
Measurement Parameters:
OSHA-80 OSHA-90 MSHA-80 MSHA-90 DOD ACGIH ISO–85 ISO–90 User1-9 SLM
DOSE% DOSE% DOSE% DOSE% DOSE% DOSE% DOSE% DOSE% DOSE% SPL
PDOSE% PDOSE% PDOSE% PDOSE% PDOSE% PDOSE% PDOSE% PDOSE% PDOSE% MAX
TWA TWA TWA TWA TWA LEPd LEPd LEPd TWA LEQ
PTWA PTWA PTWA PTWA PTWA LEQ LEQ LEQ PTWA PKZ
LAVG LAVG LAVG LAVG LAVG SEL SEL SEL LAVG SEL
LEQ LEQ LEQ LEQ LEQ SE(Pa2h) SE(Pa2h) SE(Pa2h) LEPd  
SEL SEL SEL SEL SEL MAX MAX MAX LEQ  
MAX MAX MAX MAX MAX PKZ PKZ PKZ SEL  
PKZ PKZ PKZ PKZ PKZ L10 L10 L10 SE(Pa2h)  
L10 L10 L10 L10 L10 L50 L50 L50 MAX  
L50 L50 L50 L50 L50 L90 L90 L90 PKZ  
L90 L90 L90 L90 L90 L95 L95 L95 L10  
L95 L95 L95 L95 L95 L99 L99 L99 L50  
L99 L99 L99 L99 L99 SPL SPL SPL L90  
SPL SPL SPL SPL SPL       L95  
                99  
                SPL  
Product Images
Standard Accessories
  • Main Unit
  • External Probe
  • Screwdriver
  • Carrying Case (B04)
  • Operation Manual