| Brand Name: | 3nh,Bestone |
| Model Number: | YH1100 YH1000 |
| MOQ: | 1 |
| Delivery Time: | 5-8 Working days |
| Payment Terms: | T/T |
The YH1100 and YH1000 haze meters easily perform ASTM D1003 non-compensation method testing, full light transmittance measurement, and haze testing. The open sample bin supports both vertical and horizontal testing to accommodate a wider range of samples. Both models use a PD array detector to meet the CIE V(λ) 2-degree visual response. The compensation method enables high-precision, highly repeatable measurement of light transmittance and haze.
Meets a variety of testing requirements and complies with the following standards: ASTM D1003/1044, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, and JIS K7136.
Equipped with a large-size touch screen for easy operation. The PD array detector and CIE V(λ) 2-degree visual response enable high-precision, repeatable transmittance and haze measurements. A USB data output device allows docking with laboratory systems.
An independent light source detector and temperature sensor continuously monitor light source and environmental changes, ensuring the reliability of test data.
The open sample bin allows vertical and horizontal testing, accommodating a broad range of sample types and sizes.
Provides powerful software for measuring and analyzing haze and light transmittance, suitable for quality monitoring and tabulated management of haze and transmittance data across various industries. User management is digitized at the PC end, haze and light transmittance differences can be compared, and test report forms can be generated to facilitate customer customization and management.

| Model | YH1100 | YH1000 |
|---|---|---|
| Optical Geometry | Transmission: 0/D (parallel light illumination, diffuse reflection reception) | |
| Standards Compliant | ASTM D1003/1044, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, JIS K7136 | |
| Integrating Sphere Size | Φ154mm | |
| Illuminant | 400–700nm LED light source | |
| Sensor | PD array detector, meeting CIE V(λ) 2-degree visual response | |
| Transmittance Range | 0–100% | |
| Measuring Aperture | Φ20mm / Φ15mm / Φ8mm / Φ4mm (choose one) | |
| Sample Size | Thickness less than 170mm | |
| Other Colorimetric Data | Haze (ASTM, ISO), transmittance T (ASTM) | |
| Observer Angle | 2° | |
| Illuminants | D65, A, C | |
| Displayed Data | Pass/fail result | |
| Measuring Time | Approx. 1.5s | |
| Precision | 0.01 | 0.1 |
| Repeatability | Φ20mm caliber, < 0.08 (after the instrument is warmed up and corrected, the standard deviation value of the standard haze sheet with a haze of about 40 is tested at an interval of 5s) | Φ20mm caliber, < 0.1 (after the instrument is warmed up and corrected, the standard deviation value of the standard haze sheet with a haze of about 40 is tested at an interval of 5s) |
| Inter-instrument Error | Φ20mm caliber, < 0.4 (after the instrument is warmed up and corrected, test the standard deviation of the haze standard haze sheet and the reference value at an interval of 5s) | |
| Size | Length × Width × Height = 290 × 211 × 511mm | |
| Weight | Approx. 7.6kg | |
| Power Supply | DC 24V, 3A power adapter | |
| Light Source Device Life | 5 years, more than 3 million measurements | |
| Display | 7" TFT capacitive touch screen display | |
| Data Port | USB & print serial port | |
| Data Storage | Standard 1000 pcs, sample 20000 pcs | Standard 1000 pcs, sample 20000 pcs |
| Language | Simplified Chinese, Traditional Chinese, English | |
| Working Environment | Temperature: 0–40°C; Humidity: 0–85% (no condensation) | |
| Storage Environment | Temperature: −20–50°C; Humidity: 0–85% (no condensation) | |
| Standard Accessory | Power adapter, manual, quality management software (download from official website), data cable, 0% calibration box, measuring caliber | |
| Optional Accessory | Micro printer, test fixture, standard haze film, foot switch | |
| Notes | Specifications are subject to change without notice. | |