Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Optical Meters
Created with Pixso. Double Standard ISO ASTM Haze Meter YH1200 Touch Screen Transmission Meter with Dynamic Measurement

Double Standard ISO ASTM Haze Meter YH1200 Touch Screen Transmission Meter with Dynamic Measurement

Brand Name: 3nh
Model Number: YH1200
MOQ: 1
Delivery Time: 5-8 Working days
Payment Terms: T/T
Detail Information
Place of Origin:
CHINA
Certification:
CE,FC
Optical Geometry:
0/D
Integrating Sphere Size:
Ф154 Mm
Transmittance Range:
0-100%
Measuring Aperture:
Ф20 Mm /Ф15 Mm /Ф8 Mm /Ф4 Mm
Max Sample Thickness:
<170 Mm
Measuring Time:
Approx. 1.5 S
Packaging Details:
Paper carton
Highlight:

Double Standard ISO ASTM Haze Meter

,

Touch Screen Transmission Meter

,

Dynamic Measurement Haze Meter

Product Description
Product Overview

The YH1200 haze meter easily achieves ASTM D1003 non-compensation method testing, along with full light transmittance and haze measurement. Its open sample bin supports both vertical and horizontal testing to accommodate a wider range of samples. Equipped with a PD array detector, the YH1200 meets the CIE V(λ) 2° visual response requirement. The compensation method enables high-precision, repeatable measurement of light transmittance and haze.

Technical Advantages
1. Dual Standard Compliance: ISO & ASTM

Meets the testing standard requirements of different users, in accordance with ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, and JIS K7136.

2. Easy Operation, Faster and More Accurate Measurement

The YH1200 is equipped with a large-size touch screen for straightforward operation. A PD array detector with CIE V(λ) 2° visual response ensures high-precision, repeatable transmittance and haze measurements. A USB data output device supports docking with laboratory systems.

3. Dynamic Measurement

An independent light source detector and temperature sensor continuously monitor light source and environmental changes, ensuring the reliability of test data.

4. Compensation Port for Enhanced Accuracy

Supports ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, and haze testing, delivering more accurate test results.

5. Easy Measurement, Widely Applicable to Samples

The open measuring area supports both vertical and horizontal testing, making it suitable for a broader range of samples.

6. Quality Control Software

Powerful software is provided for measuring and analyzing haze and light transmittance, suitable for quality monitoring and tabulated management of haze and light transmittance data across various industries. User management is digitized at the PC end, differences in haze and light transmittance are compared, and test report forms are generated to facilitate customer customization and management.

Applications

The YH1200 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, the packaging industry, liquid pharmaceutical analysis, and other fields.

Technical Specifications
Item Parameter
ModelYH1200
Optical GeometryTransmission: 0/D (parallel light illumination, diffuse reflection reception)
Compliant StandardsASTM D1003-1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K 7105, JIS K 6714, JIS K 7163
Integrating Sphere SizeФ154 mm
Illuminant400-700 nm full spectrum LED light source
SensorPD array detector, meets CIE V(λ) 2° visual response
Transmittance Range0-100%
Measuring ApertureФ20 mm / Ф15 mm / Ф8 mm / Ф4 mm (select one)
Max Sample Thickness<170 mm
Measured ParametersHaze (ASTM D1003/1044, ISO 13468), Transmittance T(ISO), Transmittance T(ASTM)
Observer Angle2°
Illuminants OptionD65, A, C
Displayable ResultPass / Fail judgement
Measuring TimeApprox. 1.5 s
Display Resolution0.01
RepeatabilityФ20 mm aperture: <0.05 (after instrument preheating and correction, test the standard nebulizer with a nebulization of about 30 at an interval of 5 s for 30 times of standard deviation)
Inter-instrument ErrorФ20 mm aperture: <0.4 (pre-heat and calibrate instrument; test haze standard sheet, compare with reference value for standard deviation)
Dimension (L*W*H)290 * 211 * 511 mm
WeightApprox. 7.6 kg
Power SupplyDC 24V, 3A power adapter
Light-source Service Life5 years; over 3,000,000 measurements
Display7-inch TFT capacitive touch screen
Data InterfaceUSB & Print serial port
Data StorageStandard: 1000 groups; Sample: 20,000 pieces
Available LanguageSimplified Chinese, Traditional Chinese, English
Working EnvironmentTemperature: 0-40 ℃; Humidity: 0-85% (non-condensing)
Storage EnvironmentTemperature: -20-50 ℃; Humidity: 0-85% (non-condensing)
Standard AccessoryPower adapter, manual, quality management software (download from official website), data cable, 0% calibration box, measuring caliber
Optional AccessoryMicro printer, test fixture, standard haze film, foot switch

Note: Specifications are subject to change without notice.