| Brand Name: | 3nh |
| Model Number: | YH1210 |
| MOQ: | 1 |
| Delivery Time: | 5-8 working days |
| Payment Terms: | T/T |
Designed to meet the testing standard requirements of different users. Compliant standards include ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, and JIS K7136.
The YH1210 Haze Meter features a large touch screen for easy operation. Equipped with a PD array detector, it meets the CIE V(λ) 2-degree visual response to achieve high-precision and repeatable transmittance and haze measurement. A USB data output device allows connection with laboratory systems.
An independent light source detector and temperature sensor continuously monitor light source and environmental changes, ensuring reliable test data at all times.
Supports the ASTM D1003 non-compensation method and the ISO 13468 compensation method. It performs full light transmittance and haze testing, delivering more accurate test results.
The open measurement area supports both vertical and horizontal testing, accommodating a wider range of samples under test.
Powerful software is provided for measuring and analyzing haze, color, and light transmittance. It is suitable for quality monitoring and tabulating management of haze, light transmittance, and color data across various industries. Users can manage data on a PC, compare haze, transmittance, and color differences, generate test report forms, and facilitate customized management.
| Geometry | Transmittance: 0/D (parallel illumination, diffuse receiving) in accordance with standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, JIS K7136 |
|---|---|
| Characteristic | The instrument easily realizes the ASTM D1003 uncompensated method, ISO 13468 compensation method, full transmittance, and haze test. Open measurement area for vertical and horizontal testing. Widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis, and other fields. |
| Integrating Sphere Size | Φ154 mm |
| Light Source | 400 nm to 700 nm, combined LED light source |
| Sensor | PD array detector, satisfying CIE V(λ) 2-degree visual response |
| Measurement Range | 0–100% |
| Measuring Aperture | Φ20 mm / Φ15 mm / Φ8 mm / Φ4 mm (select single aperture) |
| Sample Size | Thickness less than 105 mm |
| Other Chromaticity Index | Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM) |
| Observer Angle | 2° |
| Illuminant | D65, A, C |
| Display Data | PASS/FAIL Result |
| Measurement Time | About 1.5 s |
| Resolution | 0.01 unit |
| Repeatability | Φ20 mm aperture, less than 0.05 (after instrument preheating and correction, test the standard nebulizer with a nebulization of about 30 at an interval of 5 s for 30 times of standard deviation) |
| Inter-Instrument Error | Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5 s) |
| Dimensions | Length × Width × Height = 487 × 260 × 298 mm |
| Weight | Approx. 8.0 kg |
| Power Supply | 24 V 3 A, DC power adapter |
| Illuminant Life Span | > 3 million measurements in 5 years |
| Display | TFT true color 7 inch, capacitive touchscreen |
| Interface | USB, Print Serial |
| Data Storage | 1,000 samples, 20,000 samples |
| Language | Simplified Chinese, Traditional Chinese, English |
| Operating Temperature | 0 to 40 °C (32 to 104 °F) |
| Storage Temperature | -20 to 50 °C (-4 to 122 °F) |
| Standard Accessories | Power adapter, user guide, quality management software (download from the official website), USB cable, 0% calibration box, measuring aperture |
| Optional Accessories | Micro-printer, test fixture, standard haze sheet, foot switch |
Notes: Specifications are subject to change without notice.