Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Optical Meters
Created with Pixso. YH1810 Double Standard ISO ASTM Haze Meter with Touch Screen and Dynamic Measurement Transmission Meter for Precision Haze Testing

YH1810 Double Standard ISO ASTM Haze Meter with Touch Screen and Dynamic Measurement Transmission Meter for Precision Haze Testing

Brand Name: 3nh
Model Number: YH1810
MOQ: 1
Delivery Time: 5-8 working days
Payment Terms: T/T
Detail Information
Place of Origin:
China
Certification:
CE
Measurement Range:
0-100%
Aperture Size:
Φ20 Mm/Φ15 Mm/Φ8 Mm/Φ4 Mm
Wavelength Range:
400 ~ 700 Nm
Measurement Time:
About 1.5s
Dimensions:
487X260X298mm
Weight:
Approx. 8.0 Kg
Packaging Details:
Paper carton
Highlight:

Double Standard ISO ASTM Haze Meter

,

Touch Screen Transmission Meter

,

Dynamic Measurement Haze Tester

Product Description
Product Overview

The YH1810 Desktop Haze Meter is a professional-grade instrument engineered for precise haze and transmittance measurement. Combining dual ISO and ASTM compliance with a large touchscreen interface and advanced optical components, it delivers reliable, repeatable results for quality monitoring across glass, plastic, film, display, packaging, and liquid analysis industries.

Key Advantages
  • 1Dual ISO & ASTM Standards Meets the testing requirements of different users and complies with ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, and JIS K7136.
  • 2Simple Operation & Fast Measurement Equipped with a large-size touch screen for easy operation. A PD array detector with CIE V(λ) 2-degree visual response enables high-precision, repeatable transmittance and haze measurements. USB data output supports docking with laboratory systems.
  • 3Dynamic Measurement An independent light source detector and temperature sensor continuously monitor light source and environmental changes, ensuring the reliability of test data.
  • 4Broad Sample Compatibility Supports a wide variety of samples with an open measurement area and both vertical and horizontal testing orientations, making it suitable for diverse industrial applications.
  • 5Powerful Analysis Software Provides robust software for measuring and analyzing haze and light transmittance, suitable for quality monitoring and tabulated management across industries. User data is digitized on the PC, haze and transmittance differences are compared, and test reports are generated for easy customization and management.
  • 6Quality Management Software Delivers comprehensive software for measuring and analyzing haze, color, and light transmittance. It supports quality monitoring and tabulating management of haze, transmittance, and color data, enabling PC-based comparison of differences and generation of test report forms.
Technical Specifications
Geometry Transmittance: 0/D (parallel illumination, diffuse receiving). Conforms to ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K7136.
Characteristic The instrument easily realizes ASTM D1003 non-compensated method, ISO 13468 compensation method, full transmittance, haze test, and clarity test. It accurately collects the transmittance curve of the transmitted sample and outputs various chroma data. High hardware configuration with an open measurement area and vertical/horizontal testing. Widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis, and more.
Integrating Sphere Size Φ154 mm
Light Source 400–700 nm combined LED light source (wavelength extension customizable)
Spectrophotometric Mode Concave grating
Sensor 256-pixel dual array CMOS image sensor
Wavelength Range 400–700 nm (wavelength scalable customization)
Wavelength Interval 10 nm
Half Bandwidth 10 nm
Measurement Range 0–100%
Measuring Aperture Φ20 mm / Φ15 mm / Φ8 mm / Φ4 mm (select single aperture)
Sample Size Thickness less than 105 mm
Color Space CIE LAB, XYZ, Yxy, LCh, s-RGB, βxy, CIE LUV, Munsell, HunterLab
Chromatic Formula ΔE*ab, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00, ΔE*uv, ΔE*CH
Other Chromaticity Index Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), WI (ASTM E313, CIE/ISO, AATCC, Hunter, Taube, Berger, Stensby), YI (ASTM D1925, ASTM E313), Absorbance, Cobalt Platinum Index, Gardner Index, CMYK, Tint (ASTM E313-00), Metamerism Index Mt
Observer Angle 2° / 10°
Light Source D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30, NBF
Display Data Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result
Measurement Time Approximately 1.5 s
Resolution 0.01 unit
Repeatability Φ20 mm aperture, less than 0.05 (after instrument preheating and correction, test the standard nebulizer with a nebulization of about 30 at an interval of 5 s for 30 times of standard deviation)
Inter-Instrument Error Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5 s)
Dimensions Length × Width × Height = 487 × 260 × 298 mm
Weight Approx. 8.0 kg
Power Supply 24V 3A, DC power adapter
Illuminant Life Span > 3 million measurements in 5 years
Display TFT true color 7-inch capacitive touchscreen
Interface USB, Print Serial, Bluetooth
Data Storage 5,000 samples, 30,000 samples
Language Simplified Chinese, Traditional Chinese, English
Operating Temperature 0 to 40 °C (32 to 104 °F)
Storage Temperature -20 to 50 °C (-4 to 122 °F)
Standard Accessories Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture
Optional Accessories Micro printer, test fixture, standard haze sheet, footswitch