Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Environmental Meters
Created with Pixso. Portable TVOC Tester with 10.6eV UV Light and 0.01ppm Sensitivity for Accurate Gas Detection SPD205-TVOC-100PPM or 1000ppm

Portable TVOC Tester with 10.6eV UV Light and 0.01ppm Sensitivity for Accurate Gas Detection SPD205-TVOC-100PPM or 1000ppm

Brand Name: Bestone
Model Number: SPD205-TVOC-100 or 1000
MOQ: 1
Price: negotiable
Delivery Time: 5-8 working days
Payment Terms: T/T,Western Union,MoneyGram
Detail Information
Place of Origin:
China
Certification:
CE, RoHS
Model NO.:
SPD205-TVOC-PID
Portable:
Portable
Gas:
Tvoc
Type:
Photoionization (Pid), 10.6EV UV Light
Measurement Display:
4-Digit LCD Digital Display With Backlight
Operating Temperature:
0~40ºC(32~104ºF)
Storage Temperature:
-10~50ºC(14~122ºF)
Operating Humidity:
0~95%Rh (Relative Humidity)
Storage Humidity:
20%~80% Rh (Relative Humidity)
Concentration Unit:
Ppm (Volume Concentration), Mg/M³
Measuring Range:
0.01~100ppm(0.01-123.3 Mg/m³) Or 0.1-999.9ppm(0.1-999.9 Mg/m³)
Resolution:
When ≤20ppm: 0.01 Ppm (Isobutylene)
Resolution 2:
>20 Ppm: 0.1 Ppm (Isobutylene)
Accuracy:
±5% Ppm (Isobutylene)
Warm-up Time:
5 Seconds (Stable Work)
Display Time:
30 Seconds After The Suction Pump Inhales
Display Time 2:
The Measured Value Will Be Displayed Within 5 Seco
Alarm Mode:
Sound And Light Alarm
Sensor Principle:
Photoionization (Pid), 10.6EV UV Light
Transport Package:
Carrying Case
Packaging Details:
Plastic carrying case and paper cartons
Supply Ability:
more than 1000 units per month
Highlight:

10.6eV UV Light TVOC Tester

,

4-Digit LCD Display Gas Detector

,

0~200.0ppm Measuring Range Volatile Organic Compounds Analyzer

Product Description
Pump Suction Gas Detector
Total Volatile Organic Compounds (TVOC) Tester Model:SPD205-TVOC-100/SPD205-TVOC-1000
Portable TVOC Tester with 10.6eV UV Light and 0.01ppm Sensitivity for Accurate Gas Detection SPD205-TVOC-100PPM or 1000ppm 0
Introduction and Applications

Used to detect the concentration of total volatile organic compounds (TVOC) in the air. The detection sensitivity can reach up to 0.0lppm, using photoionization sensor (PlD). The 10.6eV purple light lamp can detect more than 100 volatile gases, and can also detect the concentration of ascertain type of gas in a targeted manner. It can detect various data such as environmental temperature, real-time concentration maximum and minimum values, STE values, TWA values, etc. It is suitable for environmental air pollution detection in factories, municipal buildings, school classrooms, conference rooms, and personnel gathering spaces.

Product Features
  1. Measurement display: 4-digit LCD display with chameleon backlight.
  2. Concentration unit: Ppm (volume specific concentration), mg/m3 (mass volume specific concentration).
  3. Range and resolution: ≤ 20ppm: 0.01 ppm (isobutylene), >20 ppm: 0.1 ppm (isobutylene)
  4. The highest measurement value can be selected: 100ppm or 1000ppm
  5. Display time: After 30 seconds of suction by the suction pump, the measured value is displayed within 5 seconds.
  6. Alarm method: Audible and visual alarm (when the alarm values exceeded, both the sound and red backlight will alert at the same time)
  7. Sensor principle: Photoionization (PlD), 10.6eV purple light.
  8. Sampling method: Built in precision suction sampling pump for sampling.
  9. Power: Standard 4x3.7V ternary lithium-ion rechargeable battery.
Portable TVOC Tester with 10.6eV UV Light and 0.01ppm Sensitivity for Accurate Gas Detection SPD205-TVOC-100PPM or 1000ppm 1
Technical Specifications
Parameter Specification
Display 4-digit LCD display
Operating temperature 0~40℃ (32~104 ℉)
Storage temperature -10~50℃(14~122℉)
Operating humidity 0~95%RH (relative humidity)
Storage humidity 20%~80% RH (relative humidity)
Concentration unit ppm (volume ratio concentration), mg/m³ (mass volume ratio concentration)
Measuring range 0.01~100ppm(0.01-123.3 mg/m³) or 0.1-999.9ppm(0.1-999.9 mg/m³)
Resolution When ≤20ppm: 0.01 ppm (isobutylene)
>20 ppm: 0.1 ppm (isobutylene)
0.1-999.9ppm:0.1ppm(isobutylene)
Accuracy ±5% ppm (isobutylene)
Warm-up time 5 seconds (stable work)
Display time 30 seconds after the suction pump inhales, the measured value will be displayed within 5 seconds
Over-range display --OL--
Alarm mode Audible and visual alarm (when the alarm values exceeded, both the sound and red backlight will alert at the same time)
Sensor principle photoionization (PID), 10.6eV UV light
Sampling method Built in precision suction sampling pump for sampling.
Calibration gas Isobutylene gas calibration, calibration factor = 1.00
Power supply Standard 4x3.7V ternary lithium-ion rechargeable battery (14500)
Physical Specifications
Component Dimensions
Size 235*74*40(mm)
Weight 1000g
Package Contents
  • Main Unit
  • Instruction manual
  • Standard 4x3.7V ternary lithium-ion rechargeable battery.
  • Charger
  • Carrying case
Portable TVOC Tester with 10.6eV UV Light and 0.01ppm Sensitivity for Accurate Gas Detection SPD205-TVOC-100PPM or 1000ppm 2 Portable TVOC Tester with 10.6eV UV Light and 0.01ppm Sensitivity for Accurate Gas Detection SPD205-TVOC-100PPM or 1000ppm 3