5750A is a halogen gas detector for industrial use,suitable for all gases and occasions.
* Detect refrigerant gas leaks in air conditioning or refrigeration systems and storage/recover containers these detectors will respond to all halogenated(contains chlorine or fluorine)refrigerants. This includes,but is not limited to:
CFCs e.g.R12,R11,R500,R503 etc...
HCFCs e.g.R22,R123,R124,R502 etc...
* Detect Ethylene Oxide gas leaks in hospital sterilizing equipment(detects halogenated propellant)
* Detect most gases that contain chlorine, fluorine and bromine(halogen gases)
* Detect halon gases in fire extinguishing systems.
Features:
* Detects all halogenated refrigerants
* Long flexible stainless probe reaches all areas
* Enhanced electronic circuitry
* Constant power indication
* Rapid warm up
* Cordless and portable,operates on 1 rechargable Li- batteries
* Super sensitive,responds to minute traces of halogen gases
* LED leak intensity indicators show relative leak size
* Attach a charger to charger
* Charge status indicator
Technical specification:
* Power supply:3.7V DC Li-battery rechargable
* Maximum sensitivity: for R12,R22 and R134A@0.5oz/yr.(14gr/yr.)
* Operating temperature: -10°C to 50°C(14°F to 122°F)
* Battery life: Approximately 2 years normal use
* Response time: Instantaneous
* Warm-up time: 5 to 6 seconds
* Unit weight: 175g
* Unit dimensions: 120* 65* 25mm
* Probe cord length: 300mm
* Package Size: Approx. 22.5 * 11.1 * 5.5cm / 8.9 * 4.4 * 2.2in (L * W * H)
* Package Weight: Approx. 265g / 9.4oz
Accessories:
* Main Unit x 1pc
* Manaul x 1pc
* USB and adapter x 1sets
* Li-battery x 1pc
* Packing box x 1pc