Products
- Electrical safety & Testing Instruments
-
Electrical safety & Testing Instruments
Proudct name:Voltage/mA Calibrator MS7221
Mode:MS7221
Measuring range:
HS Code:9031809090
Catalog PDF:
Previous:
True RMS Value Digital Multimeter ADM08A
Next:
No information
- Applications
- Key Features
- Specifications
- Accessories
MS7221 Volt/mA Calibrator is a source and measurement tool. This calibrator can be used in measurement or output o to 24mA DC Current loop, and 0 to 10V DC voltage.
* Display: 88888 counts
* Measure loop currents signals
* Measure Process signals from PLC
* Simulates 24mA loop current to output
* Source voltage to 100mV or 10V
* Low Battery Display
* Maximum voltage applied between any jack and earth ground or any tow jack: 30V
* Storage temperature: -40℃ to 60℃
* Operating temperature: -10℃ to 55℃
* Operating altitude: 3000 meters maximum
* Temperature coefficient: +/-0.005% of range per ℃ for the temperature range -10℃ to 18℃ and 28℃ to 55℃
* Relative humidity: 95% up to 30℃, 75% up to 40℃, 45%up to 50℃, 35% up to 55℃
* Shock: Random 2g, 5Hz to 500Hz
* Safety: 1 meter drop test
* Power requirement: 9VDC, 006P or 1604A
* Size: 190mm(L) x 89mm(W) x 42mm(H)
* Weight: 350g (include battery)
* Auto Power off: 6 min
* Cancel the function of Auto Power Off: Hold Input / Output key, then press Power button. The full screen appears and the Auto Power Off is canceled. On the contrary, the Auto Power Off could be recovered after reboot the calibrator.
* Safety rating: CE(EMC) RoHS
* Measure loop currents signals
* Measure Process signals from PLC
* Simulates 24mA loop current to output
* Source voltage to 100mV or 10V
* Low Battery Display
* Maximum voltage applied between any jack and earth ground or any tow jack: 30V
* Storage temperature: -40℃ to 60℃
* Operating temperature: -10℃ to 55℃
* Operating altitude: 3000 meters maximum
* Temperature coefficient: +/-0.005% of range per ℃ for the temperature range -10℃ to 18℃ and 28℃ to 55℃
* Relative humidity: 95% up to 30℃, 75% up to 40℃, 45%up to 50℃, 35% up to 55℃
* Shock: Random 2g, 5Hz to 500Hz
* Safety: 1 meter drop test
* Power requirement: 9VDC, 006P or 1604A
* Size: 190mm(L) x 89mm(W) x 42mm(H)
* Weight: 350g (include battery)
* Auto Power off: 6 min
* Cancel the function of Auto Power Off: Hold Input / Output key, then press Power button. The full screen appears and the Auto Power Off is canceled. On the contrary, the Auto Power Off could be recovered after reboot the calibrator.
* Safety rating: CE(EMC) RoHS
Specification Range Resolution Accuracy
DC V mV Input 0~100mV 0.01mV
0~10V 0.001V
DC V mV Output 0~100mV 0.01mV
0~10V 0.001V
Loop Power Output 24V DC N/A
DC mA Input 0~24 mA 0.001mA
DC mA Output 0~24 mA 0.001mA
DC V Input and Output 100mV 0.01mV +/-(0.02%+2)
10V 0.001V +/-(0.02%+2)
DC mA Input and Output 24mA 0.001mA +/-(0.015%+4)
Loop Power 24V +/-10%
DC V mV Input 0~100mV 0.01mV
0~10V 0.001V
DC V mV Output 0~100mV 0.01mV
0~10V 0.001V
Loop Power Output 24V DC N/A
DC mA Input 0~24 mA 0.001mA
DC mA Output 0~24 mA 0.001mA
DC V Input and Output 100mV 0.01mV +/-(0.02%+2)
10V 0.001V +/-(0.02%+2)
DC mA Input and Output 24mA 0.001mA +/-(0.015%+4)
Loop Power 24V +/-10%
* Main unit x 1pc
* Test lead x 2pcs
* 9V battery x 1pc
* English manual x 1pc
* Carrying case x 1pc
* Box packing x 1pc
* Test lead x 2pcs
* 9V battery x 1pc
* English manual x 1pc
* Carrying case x 1pc
* Box packing x 1pc