- Applications
- Key Features
- Specifications
- Accessories
* Large Digital LCD display
* Tests AC/DC Votage and AC/DC Current, Resistance
* Type-K thermocouple contact temperature measurement( ADM02)
* Frequency test(ADM01)
* Back light
* Auto ranging, the full scale is 2000 counts
* Data hold function
* Auto power off after 15 minutes
* Max value hold function
* Diode and continuity Test
* Low battery indication
* Safety rating: CE. CAT.II1000V CAT.III 600V, RoHS
* Power supply: 9V 6F22 battery x 1pc
Function |
Range |
Accuracy |
|||
Model |
ADM01 |
ADM02 |
|||
DC Voltage |
200mV/2V/20V/200V |
±(0.5%+2) |
±(0.5%+2) |
||
600V |
±(0.8%+2) |
±(0.8%+2) |
|||
AC Voltage |
2V/20V/200V/600V |
±(1.0%+3) |
±(1.0%+3) |
||
DC Current |
200µA/2mA/20mA/200mA |
±(1.0%+3) |
±(1.0%+3) |
||
10A |
±(3.0%+3) |
±(3.0%+3) |
|||
AC Current |
200µA/2mA/20mA/200mA |
±(1.2%+3) |
±(1.2%+3) |
||
10A |
±(3.0%+5) |
±(3.0%+5) |
|||
Resistance |
200Ω/2kΩ/20kΩ/200kΩ/2mΩ |
±(0.8%+2) |
±(0.8%+2) |
||
20mΩ |
±(1.0%+2) |
±(1.0%+2) |
|||
40mΩ |
|
|
|||
Frequency |
20kHz |
±(1.0%+2) |
|||
10kHz |
|
|
|||
Temperature(°C)( °F) |
-20°C~1000°C |
±(3.0%+3) |
|||
Feature |
|||||
Display |
200 counts |
2000 counts |
|||
Auto range |
√ |
√ |
|||
Data hold |
√ |
√ |
|||
Back light |
√ |
√ |
|||
Diode test |
√ |
√ |
|||
Continuity |
√ |
√ |
|||
Maximum value hold |
√ |
√ |
|||
General |
|||||
Power supply |
9V 6F22 Battery |
||||
Weight |
Approx 110g |
||||
Size |
140x67x30mm |
||||
Safety Rating |
CE, CAT.II 1000V CAT.III600V RoHS |
* Type-K thermocouple x 1pc(only for ADM02)
* Operating Manual x 1 pc
* 9V 6F22 battery x 1pc